Summary energy and building characteristics by building type for non-residential and multifamily buildings 20,000 square feet or greater that benchmark energy data with the City of Seattle.

Columns

NameSocrata field nameColumn name in sgr mountData typeDescription
Percent Electricitypercent_electricitypercent_electricityNumberElectricity as a percent of total energy consumption. 1% site EUI outliers and other identified errors have been excluded.
Percent Steampercent_steampercent_steamNumberSteam as a percent of total energy consumption. 1% site EUI outliers and other identified errors have been excluded.
Percent Gaspercent_gaspercent_gasNumberNatural gas as a percent of total energy consumption. 1% site EUI outliers and other identified errors have been excluded.
25th Percentile of EUI_25th_percentile_of_eui_25th_percentile_of_euiNumber25th Percentile non-normalized (for weather) site EUI (kBtu/sf). 1% outliers and other identified errors have been excluded.
Median Year Builtmedian_year_builtmedian_year_builtNumberMedian year built of buildings used to compute EUI metrics.
Minimum EUIminimum_euiminimum_euiNumberMinimum non-normalized (for weather) site EUI (kBtu/sf). 1% outliers and other identified errors have been excluded.
75th Percentile of EUI_75th_percentile_of_eui_75th_percentile_of_euiNumber75th non-normalized (for weather) site EUI (kBtu/sf). 1% outliers and other identified errors have been excluded.
Percent Otherpercent_otherpercent_otherNumberOther energy consumption (e.g. fuel oil or chilled water) as a percent of total energy consumption. 1% site EUI outliers and other identified errors have been excluded.
Median Gross Floor Areamedian_gross_floor_areamedian_gross_floor_areaNumberMedian building floor area of buildings used to compute EUI metrics.
Building Typebuilding_typebuilding_typeText'Portfolio Manager (PM) Calculated Defined Property Type. Low-rise multifamily=1-4 floors, Mid-rise multifamily=5-9 floors, High-rise multifamily=10+ floors. Small office=20,000-100,000 square feet, Large office=100,000+ square feet are categories created by City of Seattle for further refinement of PM type. Seattle Public School buildings are reporting the academic year of September 2014-August 2015. All other K-12 schools and building types are reporting the calendar year 2015 (January – December 2015).
Median Site EUImedian_site_euimedian_site_euiNumberMedian non-normalized (for weather) site EUI (kBtu/sf). 1% outliers and other identified errors have been excluded.
Total Gross Floor Areatotal_gross_floor_areatotal_gross_floor_areaNumberTotal gross floor area (sf) reported by buildings used to compute EUI metrics.
Median Site EUI Weather Normalizedmedian_site_eui_weather_normalizedmedian_site_eui_weather_normalizedNumberMedian weather-normalized site EUI (kBtu/sf). 1% outliers and other identified errors have been excluded.
Number of Bulidings with ENERGY STAR Scorenumber_of_bulidings_with_energy_star_scorenumber_of_bulidings_with_energy_star_scoreNumberNumber of buildings with a valid ENERGY STAR score
Number of Buildingsnumber_of_buildingsnumber_of_buildingsNumberNumber of buildings used to compute EUI metrics.
Median ENERGY STAR Scoremedian_energy_star_scoremedian_energy_star_scoreNumberMedian 1-100 ENERGY STAR Score.
Median Source EUImedian_source_euimedian_source_euiNumberMedian non-normalized (for weather) source EUI (kBtu/sf). 1% site EUI outliers and other identified errors have been excluded.
Maximum EUImaximum_euimaximum_euiNumberMaximum non-normalized (for weather) site EUI (kBtu/sf). 1% outliers and other identified errors have been excluded.